Reference Guide

Table Of Contents
NOTE: Some alert messages relating to an enclosure or an enclosure component, such as a fan or EMM, are generated by
the controller when the enclosure or enclosure component ID cannot be determined.
NOTE: A, B, C and X, Y, Z in the following examples are variables representing the storage object name or number.
Table 4. Message Format with Variables for Each Storage Object
Storage Object Message Variables
Controller
Message Format: Controller A (Name)
Message Format: Controller A
For example, 2326 A foreign configuration has been detected: Controller 1 (PERC 5/E
Adapter)
NOTE: The controller name is not always displayed.
Battery
Message Format: Battery X Controller A
For example, 2174 The controller battery has been removed: Battery 0 Controller 1
SCSI Physical Disk
Message Format: Physical Disk X:Y Controller A, Connector B
For example, 2049 Physical disk removed: Physical Disk 0:14 Controller 1, Connector 0
SAS Physical Disk
Message Format: Physical Disk X:Y:Z Controller A, Connector B
For example, 2049 Physical disk removed: Physical Disk 0:0:14 Controller 1, Connector 0
Virtual Disk
Message Format: Virtual Disk X (Name) Controller A (Name)
Message Format: Virtual Disk X Controller A
For example, 2057 Virtual disk degraded: Virtual Disk 11 (Virtual Disk 11) Controller 1 (PERC
5/E Adapter)
NOTE: The virtual disk and controller names are not always displayed.
Enclosure
Message Format: Enclosure X:Y Controller A, Connector B
For example, 2112 Enclosure shutdown: Enclosure 0:2 Controller 1, Connector 0
SCSI Power Supply
Message Format: Power Supply X Controller A, Connector B, Target ID C
where "C" is the SCSI ID number of the enclosure management module (EMM) managing the
power supply.
For example, 2122 Redundancy degraded: Power Supply 1, Controller 1, Connector 0, Target ID
6
SAS Power Supply
Message Format: Power Supply X Controller A, Connector B, Enclosure C
For example, 2312 A power supply in the enclosure has an AC failure: Power Supply 1,
Controller 1, Connector 0, Enclosure 2
SCSI Temperature Probe
Message Format: Temperature Probe X Controller A, Connector B, Target ID C
where C is the SCSI ID number of the EMM managing the temperature probe.
For example, 2101 Temperature dropped below the minimum warning threshold: Temperature
Probe 1, Controller 1, Connector 0, Target ID 6
SAS Temperature Probe
Message Format: Temperature Probe X Controller A, Connector B, Enclosure C
For example, 2101 Temperature dropped below the minimum warning threshold: Temperature
Probe 1, Controller 1, Connector 0, Enclosure 2
SCSI Fan
Message Format: Fan X Controller A, Connector B, Target ID C
where C is the SCSI ID number of the EMM managing the fan.
60 Storage Management Message Reference