Reference Guide

Table Of Contents
Table 8. Processor Status Events (continued)
Event Message Severity Cause
CPU <number> is absent.
Critical This event is generated when the system
could not detect the processor.
CPU <number> is operating
correctly.
Information This event is generated when the
processor recovered from an error.
CPU <number> is configured
correctly.
Information The specified CPU is configured
correctly.
Power Supply Events
The power supply sensors monitor the functionality of the power supplies. These messages provide status and warning
information for power supplies for a particular system.
Table 9. Power Supply Events
Event Message Severity Cause
<Power Supply Sensor Name>
power supply sensor removed.
Critical This event is generated when the power
supply sensor is removed.
<Power Supply Sensor Name>
power supply sensor AC
recovered.
Information This event is generated when the power
supply has been replaced.
<Power Supply Sensor Name>
power supply sensor returned
to normal state.
Information This event is generated when the power
supply that failed or removed was
replaced and the state has returned to
normal.
<Entity Name> PS Redundancy
sensor redundancy degraded.
Information Power supply redundancy is degraded
if one of the power supply sources is
removed or failed.
<Entity Name> PS Redundancy
sensor redundancy lost.
Critical Power supply redundancy is lost if only
one power supply is functional.
<Entity Name> PS Redundancy
sensor redundancy regained.
Information This event is generated if the power
supply has been reconnected or
replaced.
<Power Supply Sensor Name>
predictive failure was
asserted.
Critical This event is generated when the power
supply is about to fail.
<Power Supply Sensor Name>
input lost was asserted.
Critical This event is generated when the power
supply is unplugged.
<Power Supply Sensor Name>
predictive failure was
deasserted.
Information This event is generated when the power
supply has recovered from an earlier
predictive failure event.
<Power Supply Sensor Name>
input lost was deasserted.
Information This event is generated when the power
supply is plugged in.
PS 1 Status: Power supply
sensor for PS 1, presence was
asserted.
Information This event is generated when the power
supply is plugged in.
PS 1 Status: Power supply
sensor for PS 1, presence was
deasserted.
Critical This event is generated when the power
supply is removed.
198 System Event Log Messages for IPMI Systems