Reference Guide
Table Of Contents
- Dell EMC OpenManage Message Reference Guide Version 10.1.0.0
- Contents
- Introduction
- Server Management Messages
- Server Administrator General Messages
- Event ID — 0000
- Event ID — 0001
- Event ID — 1000
- Event ID — 1001
- Event ID — 1002
- Event ID – 1003
- Event ID — 1004
- Event ID — 1005
- Event ID — 1006
- Event ID — 1007
- Event ID — 1008
- Event ID — 1009
- Event ID — 1011
- Event ID — 1012
- Event ID — 1013
- Event ID — 1014
- Event ID — 1015
- Event ID — 1016
- Event ID — 1017
- Event ID — 1018
- Event ID — 1019
- Event ID — 1020
- Temperature Sensor Messages
- Cooling Device Messages
- Voltage Sensor Messages
- Current Sensor Messages
- Chassis Intrusion Messages
- Drive bay Intrusion Messages
- Redundancy Unit Messages
- Power Supply Messages
- Memory Device Messages
- Event ID — 1400
- Event ID — 1401
- Event ID — 1402
- Event ID — 1403
- Event ID — 1404
- Event ID — 1405
- Event ID — 1425
- Event ID — 1426
- Event ID — 1427
- Event ID — 1428
- Event ID — 1429
- Event ID — 1430
- Event ID — 1431
- Event ID — 1432
- Event ID — 1433
- Event ID — 1434
- Event ID — 1435
- Event ID — 1436
- Event ID — 1437
- Event ID — 1438
- Event ID — 1439
- Event ID — 1440
- Event ID — 1441
- Event ID — 1801
- Event ID — 1802
- Event ID — 1803
- Event ID — 1804
- Event ID — 1805
- Event ID — 1806
- Event ID — 1807
- Event ID — 1808
- Event ID — 1809
- Event ID — 1810
- Event ID — 1811
- Event ID — 1812
- Event ID — 1813
- Event ID — 1814
- Event ID — 1815
- Event ID — 1816
- Event ID — 1817
- Event ID — 1818
- Event ID — 1819
- Event ID — 1820
- Event ID — 1821
- Event ID — 1822
- Event ID — 1823
- Event ID — 1824
- Hardware Log Sensor Messages
- Processor Sensor Messages
- Pluggable Device Messages
- Battery Sensor Messages
- Secure Digital SD Card Device Messages
- Server Administrator General Messages
- Storage Management Message Reference
- Alert Monitoring and Logging
- Alert Message Format with Substitution Variables
- Alert Descriptions and Corrective Actions
- Event ID — 2048
- Event ID — 2049
- Event ID — 2050
- Event ID — 2051
- Event ID — 2052
- Event ID — 2053
- Event ID — 2054
- Event ID — 2055
- Event ID — 2056
- Event ID — 2057
- Event ID — 2058
- Event ID — 2059
- Event ID — 2060
- Event ID — 2061
- Event ID — 2062
- Event ID — 2063
- Event ID — 2064
- Event ID — 2065
- Event ID — 2067
- Event ID — 2070
- Event ID — 2074
- Event ID — 2075
- Event ID — 2076
- Event ID — 2077
- Event ID — 2079
- Event ID — 2080
- Event ID — 2081
- Event ID — 2082
- Event ID — 2083
- Event ID — 2085
- Event ID — 2086
- Event ID — 2087
- Event ID — 2088
- Event ID — 2089
- Event ID — 2090
- Event ID — 2091
- Event ID — 2092
- Event ID — 2094
- Event ID — 2095
- Event ID — 2098
- Event ID — 2099
- Event ID — 2100
- Event ID — 2101
- Event ID — 2102
- Event ID — 2103
- Event ID — 2104
- Event ID — 2105
- Event ID — 2106
- Event ID — 2107
- Event ID — 2108
- Event ID — 2109
- Event ID — 2110
- Event ID — 2111
- Event ID — 2112
- Event ID — 2114
- Event ID — 2115
- Event ID — 2116
- Event ID — 2117
- Event ID — 2118
- Event ID — 2120
- Event ID — 2121
- Event ID — 2122
- Event ID — 2123
- Event ID — 2124
- Event ID — 2125
- Event ID — 2126
- Event ID — 2127
- Event ID — 2128
- Event ID — 2129
- Event ID — 2130
- Event ID — 2131
- Event ID — 2132
- Event ID — 2135
- Event ID — 2136
- Event ID — 2137
- Event ID — 2138
- Event ID — 2139
- Event ID — 2140
- Event ID — 2141
- Event ID — 2142
- Event ID — 2143
- Event ID — 2144
- Event ID — 2145
- Event ID — 2146
- Event ID — 2147
- Event ID — 2148
- Event ID — 2149
- Event ID — 2150
- Event ID — 2151
- Event ID — 2152
- Event ID — 2153
- Event ID — 2154
- Event ID — 2155
- Event ID — 2156
- Event ID — 2157
- Event ID — 2158
- Event ID — 2159
- Event ID — 2160
- Event ID — 2161
- Event ID — 2162
- Event ID — 2163
- Event ID — 2164
- Event ID — 2165
- Event ID — 2166
- Event ID — 2167
- Event ID — 2168
- Event ID — 2169
- Event ID — 2170
- Event ID — 2171
- Event ID — 2172
- Event ID — 2173
- Event ID — 2174
- Event ID — 2175
- Event ID — 2176
- Event ID — 2177
- Event ID — 2178
- Event ID — 2179
- Event ID — 2180
- Event ID — 2181
- Event ID — 2182
- Event ID — 2183
- Event ID — 2184
- Event ID — 2185
- Event ID — 2186
- Event ID — 2187
- Event ID — 2188
- Event ID — 2189
- Event ID — 2190
- Event ID — 2191
- Event ID — 2192
- Event ID — 2193
- Event ID — 2194
- Event ID — 2195
- Event ID — 2196
- Event ID — 2197
- Event ID — 2198
- Event ID — 2199
- Event ID — 2200
- Event ID — 2201
- Event ID — 2202
- Event ID — 2203
- Event ID — 2204
- Event ID — 2205
- Event ID — 2206
- Event ID — 2207
- Event ID — 2210
- Event ID — 2211
- Event ID — 2212
- Event ID — 2213
- Event ID — 2214
- Event ID — 2215
- Event ID — 2216
- Event ID — 2217
- Event ID — 2218
- Event ID — 2219
- Event ID — 2220
- Event ID — 2221
- Event ID — 2222
- Event ID — 2223
- Event ID — 2224
- Event ID — 2225
- Event ID — 2226
- Event ID — 2227
- Event ID — 2228
- Event ID — 2229
- Event ID — 2230
- Event ID — 2231
- Event ID — 2232
- Event ID — 2233
- Event ID — 2234
- Event ID — 2235
- Event ID — 2236
- Event ID — 2237
- Event ID — 2238
- Event ID — 2239
- Event ID — 2240
- Event ID — 2241
- Event ID — 2242
- Event ID — 2243
- Event ID — 2244
- Event ID — 2245
- Event ID — 2246
- Event ID — 2247
- Event ID — 2248
- Event ID — 2249
- Event ID — 2250
- Event ID — 2251
- Event ID — 2252
- Event ID — 2253
- Event ID — 2254
- Event ID — 2255
- Event ID — 2257
- Event ID — 2258
- Event ID — 2259
- Event ID — 2260
- Event ID — 2261
- Event ID — 2262
- Event ID — 2263
- Event ID — 2264
- Event ID — 2265
- Event ID — 2266
- Event ID — 2267
- Event ID — 2268
- Event ID — 2269
- Event ID — 2270
- Event ID — 2271
- Event ID — 2272
- Event ID — 2273
- Event ID — 2274
- Event ID — 2276
- Event ID — 2277
- Event ID — 2278
- Event ID — 2279
- Event ID — 2280
- Event ID — 2281
- Event ID — 2282
- Event ID — 2283
- Event ID — 2284
- Event ID — 2285
- Event ID — 2286
- Event ID — 2287
- Event ID — 2288
- Event ID — 2289
- Event ID — 2290
- Event ID — 2291
- Event ID — 2292
- Event ID — 2293
- Event ID — 2294
- Event ID — 2295
- Event ID — 2296
- Event ID — 2297
- Event ID — 2298
- Event ID — 2299
- Event ID — 2300
- Event ID — 2301
- Event ID — 2302
- Event ID — 2303
- Event ID — 2304
- Event ID — 2305
- Event ID — 2306
- Event ID — 2307
- Event ID — 2309
- Event ID — 2310
- Event ID — 2311
- Event ID — 2312
- Event Id — 2313
- Event ID — 2314
- Event Id — 2315
- Event ID — 2316
- Event ID — 2318
- Event ID — 2319
- Event Id — 2320
- Event ID — 2321
- Event ID — 2322
- Event ID — 2323
- Event ID — 2324
- Event ID — 2325
- Event ID — 2326
- Event ID — 2327
- Event ID — 2328
- Event ID — 2329
- Event ID — 2330
- Event ID — 2331
- Event ID — 2332
- Event ID — 2334
- Event ID — 2335
- Event ID — 2336
- Event ID — 2337
- Event ID — 2338
- Event ID — 2339
- Event ID — 2340
- Event ID — 2341
- Event ID — 2342
- Event ID — 2343
- Event ID — 2344
- Event ID — 2345
- Event ID — 2346
- Event ID — 2347
- Event ID — 2348
- Event ID — 2349
- Event ID — 2350
- Event ID — 2351
- Event ID — 2352
- Event ID — 2353
- Event ID — 2354
- Event ID — 2355
- Event ID — 2356
- Event ID — 2357
- Event ID — 2358
- Event ID — 2359
- Event ID — 2360
- Event ID — 2361
- Event ID — 2362
- Event ID — 2364
- Event ID — 2366
- Event ID — 2367
- Event ID — 2368
- Event ID — 2369
- Event ID — 2370
- Event ID — 2371
- Event ID — 2372
- Event ID — 2373
- Event ID — 2374
- Event ID — 2375
- Event ID — 2376
- Event ID — 2377
- Event ID — 2378
- Event ID — 2379
- Event ID — 2380
- Event ID — 2381
- Event ID — 2382
- Event ID — 2383
- Event ID — 2384
- Event Id — 2385
- Event ID — 2386
- Event ID — 2387
- Event ID — 2388
- Event ID — 2389
- Event ID — 2390
- Event ID — 2392
- Event ID — 2393
- Event ID — 2394
- Event ID — 2395
- Event ID — 2396
- Event ID — 2397
- Event ID — 2398
- Event ID — 2399
- Event ID — 2400
- Event ID — 2401
- Event ID — 2402
- Event ID — 2403
- Event ID — 2404
- Event ID — 2405
- Event ID — 2407
- Event ID — 2411
- Event ID — 2412
- Event ID — 2413
- Event ID — 2414
- Event ID — 2415
- Event ID — 2416
- Event ID — 2417
- Event ID — 2418
- Event ID — 2425
- Event ID — 2426
- Event ID — 2429
- Event ID — 2430
- Event ID — 2431
- Event ID — 2432
- Event ID — 2433
- Event ID — 2434
- Event ID — 2435
- Event ID — 2436
- Event ID — 2437
- Event ID — 2438
- Event ID — 2440
- Event ID — 2441
- Event ID — 2442
- Event ID — 2443
- Event ID — 2444
- Event ID — 2446
- Event ID — 2447
- Event ID — 2448
- Event ID — 2449
- Event ID — 2450
- Event ID — 2451
- Event ID — 2452
- Event ID — 2453
- Event ID — 2454
- Event ID — 2457
- Event ID — 2458
- Event ID — 2459
- Event ID — 2460
- Event ID — 2461
- Event ID — 2462
- Event ID — 2463
- Event ID — 2464
- Event ID — 2467
- Event ID — 2468
- Event ID — 2469
- Event ID — 2470
- Event ID — 2476
- Event ID — 2477
- Event ID — 2478
- Event ID — 2479
- Event ID — 2480
- Event ID — 2482
- Event ID — 2483
- Event ID — 2484
- Event ID — 2485
- Event ID — 2486
- Event ID — 2487
- Event ID — 2488
- Event ID — 2489
- Event ID — 2490
- Event ID — 2491
- Event ID — 2492
- Event ID — 2699
- Event ID — 2700
- Event ID — 2701
- Event ID — 2702
- Event ID — 2703
- Event ID — 2704
- Event ID — 2705
- Event ID — 2874
- Event ID — 2875
- Event ID — 2876
- Event ID — 2900
- Event ID — 2901
- Event ID — 2902
- Event ID — 2903
- Event ID — 2904
- Event ID — 2905
- Event ID — 2906
- Event ID — 2907
- Event ID — 2908
- Event ID — 2909
- Event ID — 2910
- Event ID — 2911
- Event ID — 2912
- Event ID — 2913
- Event ID — 2914
- Event ID — 2915
- Event ID — 2916
- Event ID — 2917
- Event ID — 2918
- Event ID — 2919
- Event ID — 2920
- Event ID — 2921
- Event ID — 2922
- Event ID — 2923
- Event ID — 2924
- Event ID — 2930
- Event ID — 2931
- Event ID — 2932
- Event ID — 2933
- System Event Log Messages for IPMI Systems
- Temperature Sensor Events
- Voltage Sensor Events
- Fan Sensor Events
- Processor Status Events
- Power Supply Events
- Memory ECC Events
- BMC Watchdog Events
- Memory Events
- Hardware Log Sensor Events
- Drive Events
- Intrusion Events
- BIOS Generated System Events
- POST Code Table
- Operating System Generated System Events
- Cable Interconnect Events
- Battery Events
- Power And Performance Events
- Entity Presence Events
- Miscellaneous Events
Table 7. Fan Sensor Events (continued)
Event Message Severity Cause
<Sensor Name/Location> Fan
Redundancy sensor redundancy
lost.
Critical The fan specified by <Sensor Name/
Location> may have failed and hence,
the redundancy that was degraded
previously has been lost.
<Sensor Name/Location> Fan
Redundancy sensor redundancy
regained
Information The fan specified by <Sensor Name/
Location> may have started functioning
again and hence, the redundancy has
been regained.
Fan <number> RPM is less than
the lower warning threshold.
Warning The speed of the specified fan might not
provide enough cooling to the system.
Fan <number> RPM is less than
the lower critical threshold.
Critical The speed of the specified fan is not
sufficient to provide enough cooling to
the system.
Fan <number> RPM is greater
than the upper warning
threshold.
Warning The speed of the specified fan exceeded
the warning threshold.
Fan <number> RPM is greater
than the upper critical
threshold.
Critical The speed of the specified fan exceeded
the critical threshold.
Fan <number> RPM is outside
of range.
Critical The speed of the specified fan might not
provide enough cooling to the system.
Fan <number> RPM is within
range.
Information The speed of the specified fan is
operating in a normal range.
Fan <number> is removed.
Critical A required fan was removed.
Fan <number> was inserted.
Information A fan was added.
Fan <number> is present.
Information The total number of fans present.
Fan <number> is absent.
Critical A required fan is missing.
The fans are redundant.
Information One or more fans may have started
functioning or installed and the
redundancy has been regained.
Fan redundancy is lost.
Critical One or more required fans may have
failed or removed and hence, the
redundancy was lost.
Fan redundancy is degraded.
Warning One or more fans may have failed or
removed and hence, the redundancy has
been degraded.
Processor Status Events
The processor status messages monitor the functionality of the processors in a system. These messages provide processor
health and warning information of a system.
Table 8. Processor Status Events
Event Message Severity Cause
<Processor Entity> status
processor sensor IERR, where
<Processor Entity> is the
processor that generated the
event. For example, PROC for
Critical IERR internal error generated by the
<Processor Entity>. This event is
generated due to processor internal
error.
196 System Event Log Messages for IPMI Systems