Reference Guide

Table Of Contents
Event ID 2480
Description
Unable to update the firmware on the controller because the controller key change operation is pending.
Severity Warning
Cause and Action Cause: PERC controller firmware update is blocked because the controller key change is pending.
Perform power cycle operation on the host and retry the firmware update.
Action: Perform a power-cycle operation on the host. For example, to perform power-cycle using IDRAC
RACADM Interface, run the RACADM command: racadm serveraction powercycle.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 753
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
None
Event ID 2482
Description
Multiple namespace is detected on the physical device.
Severity Informational
Cause and Action Cause: Multiple namespaces are detected on the physical disk drive identified in the message.
Action: No response action is required.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 901
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
None
Event ID 2483
Description
The drives are automatically configured by firmware.
Severity Informational
Cause and Action Cause: The drives are automatically configured by the user or firmware as identified in the message.
Action: No response action is required.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751
Event ID 2484
Description
The Auto Configuration Behavior feature on the controller is changed to <Off/ Non-RAID Disk/ RAID 0>.
Severity Informational
Storage Management Message Reference 179