Reference Guide

Table Of Contents
Event ID 2400
Description Physical disk configuration data updated as it was stale.
Severity Informational
Cause and Action Cause: The physical disk configuration data is updated because it was outdated.
Action: None.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
901
Event ID 2401
Description Configuration command could not be committed to disk. Configuration has to be re applied.
Severity Failure / Error
Cause and Action Cause: The virtual disk configuration command did not succeed.
Action: Check for the recent configuration that has not taken effect. Re-apply the configuration.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
754
Event ID 2402
Description
Changing the Physical Disk Power status from 1% to 2% failed.
Severity Failure / Error
Cause and Action Cause: When changing the Physical Disk Power status fails.
Action: Replace the physical disk.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
904
Event ID 2403
Description
Virtual Disk is available.
Severity OK / Normal / Informational
Cause and Action Cause: The operating system detects the newly created virtual disk.
Action: None.
162 Storage Management Message Reference