Reference Guide

Table Of Contents
Severity Warning / Non-critical
Cause and Action Cause: A physical disk of media type SSD is attached to a controller that does not support SSD disks.
Action: Replace the unsupported physical disk with a physical disk of media type HDD.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
903
Event ID 2383
Description The Information level set for the hot spare protection policy is violated for the Virtual Disk.
Severity OK / Normal / Informational
Cause and Action Cause: The number of physical disks you specified for the hot spare protection policy is violated.
Action: Reassign the number of hot spares as specified in the protection policy for that RAID level.
Related Alert
Information
Clear Alert Number: 2195
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1201
Event ID 2384
Description
The Warning level set for the hot spare protection policy is violated for the Virtual Disk.
Severity Warning / Non-critical
Cause and Action Cause: The number of physical disks you specified for the hot spare protection policy is violated.
Action: Reassign the number of hot spares as specified in the protection policy for that RAID level.
Related Alert
Information
Clear Alert Number: 2195
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1203
Event Id 2385
Description
The Critical level set for the hot spare protection policy is violated for the Virtual Disk.
Severity Critical / Failure / Error
Cause and Action Cause: The number of physical disks you specified for the hot spare protection policy is violated.
Action: Reassign the number of hot spares as specified in the protection policy for that RAID level.
Related Alert
Information
Clear Alert Number: 2195
Related Alert Number: None
Local Response Agent (LRA) Number: None
Storage Management Message Reference 157