Reference Guide

Table Of Contents
Local Response Agent (LRA) Number: 2061
SNMP Trap
Numbers
754
Event ID 2357
Description SAS expander error: %1.
Severity Critical / Failure / Error
Cause and Action Cause: The %1 indicates a substitution variable. The text for this substitution variable is generated by the
firmware and is displayed with the alert in the alert log. This text can vary depending on the situation.
Action: There may be a problem with the enclosure. Check the health of the enclosure and its
components by selecting the enclosure object in the tree view. The Health subtab displays a red X or
yellow exclamation point for enclosure components that are Failed or Degraded. See the enclosure
documentation for more information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2061
SNMP Trap
Numbers
754
Event ID 2358
Description
The battery charge cycle is complete.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1151
Event ID 2359
Description
Disk found is not supplied by an authorized hardware provider.
Severity Warning / Non-critical
Cause and Action Cause: The physical disk does not comply with the standards set and is not supported.
Action: Replace the physical disk with a physical disk that is supported.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
150 Storage Management Message Reference