Reference Guide

Table Of Contents
Action: Restart the initialization.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2080
SNMP Trap
Numbers
1203
Event ID 2345
Description The virtual disk initialization failed.
Severity Critical / Failure / Error
Cause and Action Cause: The controller cannot communicate with attached devices. A disk may be removed or contain
errors. Cables may also be loose or defective.
Action: Verify the health of attached devices. Review the Alert Log for significant events. Make sure
the cables are attached securely. See the Cables Attached Correctly section for more information on
checking the cables.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2081
SNMP Trap
Numbers
1204
Event ID 2346
Description
Error occurred: %1.
Severity Warning
Cause and Action Cause: A physical device may have an error. The %1 indicates a substitution variable. The text for this
substitution variable is generated by the firmware and is displayed with the alert in the alert log. This text
can vary depending on the situation.
Action: Verify the health of attached devices. Review the alert log for significant events. Run the PHY
integrity diagnostic tests. You may need to replace faulty hardware. Make sure that the cables are
attached securely. See the hardware documentation for more information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2048, 2050, 2056, 2057, 2076, 2079, 2081, 2083, 2095, 2129, 2201, 2203, 2270,
2282, 2369
Part Number= <Part Number>
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID 2347
Description
The rebuild failed due to errors on the source physical disk.
Severity Critical / Failure / Error
Cause and Action Hardware RAID: Cause and Action
146 Storage Management Message Reference