Reference Guide

Table Of Contents
SNMP Trap
Numbers
751, 801, 851, 901, 951, 1001, 1051, 1101, 1151, 1201
Event ID 2335
Description Controller event log: %1.
Severity Warning / Non-critical
Cause and Action Cause: The %1 indicates a substitution variable. The text for this substitution variable is generated by the
controller and is displayed with the alert in the alert log. This text is from events in the controller event
log that were generated while Storage Management was not running. This text can vary depending on the
situation.
Action: If there is a problem, review the controller event log and the Server Administrator alert log for
significant events or alerts that may assist in diagnosing the problem. Check the health of the storage
components. See the hardware documentation for more information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2060
SNMP Trap
Numbers
753
Event ID 2336
Description
Controller event log: %1.
Severity Critical / Failure / Error
Cause and Action Cause: The %1 indicates a substitution variable. The text for this substitution variable is generated by the
controller and is displayed with the alert in the alert log. This text is from events in the controller event
log that were generated while Storage Management was not running. This text can vary depending on the
situation.
Action: See the hardware documentation for more information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2061
SNMP Trap
Numbers
754
Event ID 2337
Description
The controller is unable to recover cached data from the battery backup unit (BBU).
Severity Critical / Failure / Error
Cause and Action Cause: The controller was unable to recover data from the cache. This may occur when the system is
without power for an extended period when the battery is discharged.
Action: Check if the battery is charged and in good health. When the battery charge is unacceptably low,
it cannot maintain cached data. Check if the battery has reached its recharge limit. The battery may need
to be recharged or replaced.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Storage Management Message Reference 143