Reference Guide

Table Of Contents
Severity Critical / Failure / Error
Cause and Action Cause: The power cable may be pulled out or removed. The power cable may also have overheated and
become warped and nonfunctional.
Action: Replace the power cable.
Related Alert
Information
Clear Alert Number: 2325
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
1004
Event ID 2325
Description The power supply cable has been inserted.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Status: Alert 2325 is a clear alert for alerts 2324 and 2312.
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1001
Event ID 2326
Description
A foreign configuration has been detected.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes. The controller has physical disks that were moved from
another controller. These physical disks contain virtual disks that were created on the other controller.
See the Import Foreign Configuration and Clear Foreign Configuration section in the Server Administrator
Storage Management Users Guide for more information.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751
Event ID 2327
Description
The NVRAM has corrupted data. The controller is reinitializing the NVRAM.
Severity Warning / Non-critical
Cause and Action Cause: The nonvolatile random access memory (NVRAM) is corrupt. This may occur after a power surge,
a battery failure, or for other reasons. The controller is reinitializing the NVRAM. The controller properties
reset to the default settings after the reinitialization is complete.
140 Storage Management Message Reference