Event ID 2321
Description Single-bit ECC error. The DIMM is critically nonfunctional. There is no further reporting.
Severity Critical / Failure / Error
Cause and Action Cause: The DIMM is malfunctioning. Data loss or data corruption is imminent. No further alerts are
generated.
Action: Replace the DIMM immediately. The DIMM is a part of the controller battery pack. See your
hardware documentation for information on replacing the DIMM.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2061
SNMP Trap
Numbers
754
Event ID 2322
Description The DC power supply is switched off.
Severity Informational
Cause and Action Cause: The power supply unit is switched off. Either a user switched off the power supply unit or it is
defective.
Action: Check if the power switch is turned off. If it is turned off, turn it on. If the problem persists,
check if the power cord is attached and functional. If the problem is still not corrected or if the power
switch is already turned on, replace the power supply unit.
Related Alert
Information
Clear Alert Number: 2323
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
1001
Event ID 2323
Description
The power supply is switched on.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Status: Alert 2323 is a clear alert for alerts 2313 and 2322.
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1001
Event ID 2324
Description
The AC power supply cable has been removed.