Reference Guide

Table Of Contents
Action: Replace the failed disks and restore from backup.
Related Alert
Information
Clear Alert Number: 1204
Related Alert Number: None
Local Response Agent (LRA) Number: 2081
SNMP Trap
Numbers
1204
Event ID 2311
Description The firmware on the EMMs is not the same version. EMM0 %1 EMM1 %2.
Severity Warning / Non-critical
Cause and Action Cause: The firmware on the EMM modules is not the same version. It is required that both modules have
the same version of the firmware. This alert may be caused if you attempt to insert an EMM module that
has a different firmware version than an existing module. The %1 and %2 indicate a substitution variable.
The text for these substitution variables is displayed with the alert in the alert log and can vary depending
on the situation.
Action: Upgrade to the same version of the firmware on both EMM modules.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2090
SNMP Trap
Numbers
853
Event ID 2312
Description
A power supply in the enclosure has an AC failure.
Severity Warning / Non-critical
Cause and Action Cause: The power supply has an AC failure.
Action: Replace the power supply.
Related Alert
Information
Clear Alert Number: 1003
Related Alert Number: 2122, 2324
Local Response Agent (LRA) Number: 2090
SNMP Trap
Numbers
1003
Event Id 2313
Description
A power supply in the enclosure has a DC failure.
Severity Warning / Non-critical
Cause and Action Cause: The power supply has a DC failure.
Action: Replace the power supply.
Related Alert
Information
Clear Alert Number: 2323
Related Alert Number: 2122, 2333
136 Storage Management Message Reference