Reference Guide

Table Of Contents
Event ID 2255
Description The physical disk has been started.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2048, 2050, 2065, 2099, 2121, 2196, 2201, 2203
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
901
Event ID 2257
Description Controller preserved cache is discarded.
Severity Warning /Non-critical
Cause and Action Cause: The controller cache is discarded by the user. This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
753
Event ID 2258
Description
Controller has preserved cache.
Severity Warning /Non-critical
Cause and Action Cause: I/O interrupted for a virtual disk which is connected to the controller.
Action: Check for foreign configuration and import if any. Check for cable fault. Recover any virtual disk
lost by the controller.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
753
Event ID 2259
Description
An enclosure blink operation has initiated.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
120 Storage Management Message Reference