Reference Guide

Table Of Contents
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID 2210
Description Battery requires reconditioning. Initiate the battery learn cycle.
Severity Warning / Non-critical
Cause and Action Cause: Battery is in warn only mode and requires reconditioning.
Action: Initiate the battery learn cycle.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1153
Event ID 2211
Description
The physical disk is not supported.
Severity Warning / Non-critical
Cause and Action Cause: The physical disk may not have a supported version of the firmware or the disk may not be
supported by your service provider.
Action: If the disk is supported, update the firmware to a supported version. If the disk is not supported
by your service provider, replace the disk with one that is supported.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID 2212
Description
The controller battery temperature is above normal.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1151
Storage Management Message Reference 107