Reference Guide

Table Of Contents
Action: Check if the disk is healthy and that it has not been removed. Check the cables. If necessary,
replace the disk and reassign the hot spare.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2048
Part Number= <Part Number>
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID 2202
Description A global hot spare has been removed.
Severity OK / Normal / Informational
Cause and Action Cause: The controller is unable to communicate with a disk that is assigned as a global hot spare. The
disk may have been removed. There may also be a bad or loose cable.
Action: Check if the disk is healthy and that it has not been removed. Check the cables. If necessary,
replace the disk and reassign the hot spare.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
901
Event ID 2203
Description
A dedicated hot spare failed.
Severity Warning
Cause and Action Cause: The controller is unable to communicate with a disk that is assigned as a dedicated hot spare. The
disk may have failed or been removed. There may also be a bad or loose cable.
Action: Check if the disk is healthy and that it has not been removed. Check the cables. If necessary,
replace the disk and reassign the hot spare.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2048
Part Number= <Part Number>
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID 2204
Description
A dedicated hot spare has been removed.
Severity OK / Normal / Informational
Cause and Action Cause: The controller is unable to communicate with a disk that is assigned as a dedicated hot spare. The
disk may have been removed. There may also be a bad or loose cable.
Storage Management Message Reference 105