Release Notes
Table Of Contents
- Dell EMC OpenManage Release Notes Version 10.0.1
- Product description
- OMSA Customer Survey
- Platforms Affected
- Requirements
- What’s new in this release
- Installation Procedure
- Known issues and workarounds for Server Administrator
- User notes
- Storage Management Service
Table 6. Known issues for Storage Management Service (continued)
Issue ID Functional area Description Workaround/Resolutions
Not available PCIe subsystems The Device name field of NVMe drives is displayed as
char device name on PCIe subsystems running on Linux
operating.
Not available
165785 Read-write policy
on S130
On S130 and later, any change in read and write policy
values while creation of virtual disks does not reflect on
virtual disk.
Use Change policy virtual
disk task for changing these
policies.
165788 Predictive failure
drives
Predictive failure drives on HBA controller displays as
ready state and the predictive failure alert is also not
generated for such drives.
Not available
167651 PCIe subsystem The Storage Management enumerates the PCIe
Subsystem controller also for 2.5'’ NVMe drives on
PERC 11.
Not available
Not available Auto-configure
RAID 0
When the auto-configure RAID 0 task is performed on
PERC 9, only HDDs that are currently in ready state will
change to RAID 0. There will be no change for SSDs.
Not available
165719 Storage Alert Log A blank page of the Storage Alert Log is displayed when
the Storage controller generates several alerts and cold
boot performed together from iDRAC.
Delete dcsys64.xml and
restart the services. The
file path where the .xml
file is available on systems
running Microsoft Window
operating system : C:\Program
Files\Dell\SysMgt\omsa\log,
on systems running ESXi
operating system : /etc/cim/
dell/srvadmin/var/log/
openmanage/ and other
operating systems : /opt/
dell/srvadmin/var/log/
openmanage/.
154358 VDs with more than
78 PDs
On Command Line Interface for RAID 10, 50, and 60
virtual disk that is created with more than 78 physical
disk, fails on external RAID PERC H840 and PERC
H830.
Not available
169111 Partial RAID-10 VDs On a partial RAID-10 virtual disk creation through
Create virtual disk advanced wizard, the drive selection
list displayed may not be similar to the actual physical
drive associated with the spans.
Not available
168698 Enumeration on
ESXi
Read Only Write-Protected drive will not enumerate on
systems running ESXi operating systems.
Not available
169839 Auto Replace
Member or
Predictive Failure
When Auto Replace Member On Predictive Failure is
enabled, it does not work for SSD.
Not available
155954 Hot plug-in multiple
drives
While hot-plug-in mulitple drives of MX5016s physically,
wait for each insert alert to avoid the wrong
enumeration.
Restart the Data manager
service to get the updated
enumeration.
Not available Controller ID and
name
If the controller name is not displayed in the alert
message, check the controller information for mapping
the controller ID and controller name.
Not available
92467 Dynamic mapping The dynamic mapping of an enclosure for the first time
also displays the unmapped enclosure for a short period.
Refresh the Server Administrator page to remove the
unmapped enclosure entries.
Not available
22