Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.0.1
- Contents
- Introduction
- What’s New in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 720. Processor Device Status (continued)
Description Defines the status of the processor device status probe. This status is joined into the
processorDeviceStatus attribute.
Syntax DellStatus
Access Read-only
Table 721. Processor Device Status Reading
Name
processorDeviceStatusReading
Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.6
Description Defines the reading of the processor device status probe.
Syntax DellProcessorDeviceStatusReading
Access Read-only
Table 722. Processor Device Status Location Name
Name
processorDeviceStatusLocationName
Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.7
Description Defines the location name of the processor device status probe.
Syntax DellString
Access Read-only
Table 723. Processor Device Status Port Index Reference
Name
processorDeviceStatusPortIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.8
Description Defines the index (one-based) of the associated processor port in the same chassis.
Syntax DellObjectRange
Access Read-only
Cache Device Table
Table 724. Cache Device Table
Name
cacheDeviceTable
Object ID 1.3.6.1.4.1.674.10892.1.1100.40
Description Defines the Cache Device Table.
Syntax SEQUENCE OF CacheDeviceTableEntry
Access Not accessible
Table 725. Cache Device Table Entry
Name
cacheDeviceTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1
Description Defines the Cache Device Table entry.
Syntax CacheDeviceTableEntry
Access Not accessible
164 Server Administrator Group