Reference Guide

Table Of Contents
Related Alert
Information
Clear Alert Number: Alert 2172 is a clear alert for alert 2171.
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1151
Event ID — 2173
Description Unsupported configuration detected. The SCSI rates of the enclosure management modules (EMMs) are
not the same. EMM 0 % 1 EMM 1 % 2
Severity Warning / Non-critical
Cause and Action Cause: An unsupported configuration was detected.
Action: Replace one of the EMMs with the matching SCSI rate EMM.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2090
SNMP Trap
Numbers
853
Event ID — 2174
Description
The controller battery has been removed.
Severity Warning / Non-critical
Cause and Action Cause: The controller cannot communicate with the battery. The battery may be removed, or the contact
point between the controller and the battery may be burnt or corroded.
Action: Replace the battery if it has been removed. If the contact point between the battery and the
controller is burnt or corroded, you must replace either the battery or the controller, or both. See the
hardware documentation for information on how to safely access, remove, and replace the battery.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2188, 2318
Local Response Agent (LRA) Number: 2100
SNMP Trap
Numbers
1153
Event ID — 2175
Description
The controller battery has been replaced.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
94