Reference Guide

Table Of Contents
SNMP Trap
Numbers
753
Event ID — 2167
Description The current kernel version and the non-RAID SCSI driver version are older than the minimum required
levels. See readme.txt for a list of validated kernel and driver versions.
Severity Warning / Non-critical
Cause and Action Cause: The version of the kernel and the driver do not meet the minimum requirements. Storage
Management may not be able to display the storage or perform storage management functions until you
have updated the system to meet the minimum requirements.
Action: See the Readme file for a list of validated kernel and driver versions. Update the system to meet the
minimum requirements and then reinstall Storage Management.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2050
SNMP Trap
Numbers
103
Event ID — 2168
Description
The non-RAID SCSI driver version is older than the minimum required level. See readme.txt for the
validated driver version.
Severity Warning / Non-critical
Cause and Action Cause: The version of the driver does not meet the minimum requirements. Storage Management may not
be able to display the storage or perform storage management functions until you have updated the system
to meet the minimum requirements.
Action: See the Readme file for the validated driver version. Update the system to meet the minimum
requirements and then reinstall Storage Management.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2050
SNMP Trap
Numbers
103
Event ID — 2169
Description
The controller battery needs to be replaced.
Severity Critical / Failure / Error
Cause and Action Cause: The controller battery cannot be recharged. The battery may be old or it may have been already
recharged the maximum number of times. In addition, the battery charger may not be working.
Action: Replace the battery pack.