Action: Check for factors that may cause overheating or excessive cooling. For example, verify that the
enclosure fan is working. You should also check the thermostat settings and examine whether the enclosure
is located near a heat source. Make sure the enclosure has enough ventilation and that the room
temperature is not too hot or too cold. See the enclosure documentation for more diagnostic information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
854
Event ID — 2114
Description A consistency check on a virtual disk has been paused (suspended).
Severity OK / Normal / Informational
Cause and Action Cause: The check consistency operation on a virtual disk was paused by a user.
Action: To resume the check consistency operation, right-click the virtual disk in the tree view and select
Resume Check Consistency.
Related Alert
Information
Clear Alert Number: 2115
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1201
Event ID — 2115
Description
A consistency check on a virtual disk has been resumed.
Severity OK / Normal / Informational
Cause and Action Cause: The check consistency operation on a virtual disk has resumed processing after being paused by a
user. This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: Alert 2115 is a clear alert for alert 2114.
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1201
Event ID — 2116
Description
A virtual disk and its mirror have been split.
Severity OK / Normal / Informational
74