Reference Guide

Table Of Contents
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2110
Description SMART warning degraded.
Severity Warning / Non-critical
Cause and Action Cause: A disk is degraded and has received a SMART alert (predictive failure). The disk is likely to fail in the
near future.
Action: Replace the disk that has received the SMART alert. If the physical disk is a member of a
nonredundant virtual disk, then back up the data before replacing the disk.
CAUTION: Removing a physical disk that is included in a non-redundant virtual disk causes the
virtual disk to fail and may cause data loss.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2111
Description
Failure prediction threshold exceeded due to test.
Severity Warning / Non-critical
Cause and Action Cause: A disk has received a SMART alert (predictive failure) due to test conditions.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2112
Description
Enclosure was shut down.
Severity Critical / Failure / Error
Cause and Action Cause: The physical disk enclosure is either hotter or cooler than the maximum or minimum allowable
temperature range.
73