Reference Guide

Table Of Contents
Event ID — 2091
Description Virtual disk rebuild completed.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: Alert 2091 is a clear alert for alert 2064.
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1201
Event ID — 2092
Description Physical disk rebuild completed.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: Alert 2092 is a clear alert for alert 2065.
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
901
Event ID — 2094
Description
Predictive Failure reported.
Severity Warning / Non-critical
Cause and Action Cause: The physical disk is predicted to fail. Many physical disks contain Self Monitoring Analysis and
Reporting Technology (SMART). When enabled, SMART monitors the health of the disk based on
indications such as the number of write operations that have been performed on the disk.
Action: Replace the physical disk. Even though the disk may not have failed yet, it is strongly recommended
that you replace the disk.
If this disk is part of a redundant virtual disk, perform the Offline task on the disk; replace the disk; the
rebuild starts automatically.
NOTE: If you put the drive in a different slot, you need to assign it as a hot spare for the rebuild to
start automatically.
If this disk is a hot spare, then unassign the hot spare; perform the Prepare to Remove task on the disk;
replace the disk; and assign the new disk as a hot spare.
67