Reference Guide

Table Of Contents
If the physical disk is part of a redundant array, then rebuild the physical disk. When finished, restart the
reconfiguration.
Software RAID:
Perform a backup with the Verify option.
If the file backup fails, try to restore the failed file from a previous backup.
When the backup with the Verify option is complete without any errors, delete the Virtual Disk.
Recreate a new Virtual Disk with new drives.
Restore the data from backup.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2081
SNMP Trap
Numbers
1204
Event ID — 2082
Description Virtual disk rebuild failed.
Severity Critical / Failure / Error
Cause and Action Cause: A physical disk included in the virtual disk has failed or is not functioning. A user may also have
cancelled the rebuild.
Action: Replace the failed or non-functional disk. You can identify a disk that has failed by locating the disk
that has a red X for its status. Restart the virtual disk rebuild.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2048
Local Response Agent (LRA) Number: 2081
SNMP Trap
Numbers
1204
Event ID — 2083
Description
Physical disk rebuild failed.
Severity Critical / Failure / Error
Cause and Action Cause: A physical disk included in the virtual disk has failed or is not functioning. A user may also have
cancelled the rebuild.
Action: Replace the failed or non-functional disk. You can identify a disk that has failed by locating the disk
that has a red X for its status. Rebuild the virtual disk rebuild.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2071
64