Description Severity Cause
A runtime critical stop
occurred.
Critical The operating system encountered a
critical error and was stopped abnormally.
An OS graceful stop occurred.
Information The operating system was stopped.
An OS graceful shut-down
occurred.
Information The operating system was shut down
normally.
Cable Interconnect Events
The cable interconnect messages in the table are used for detecting errors in the hardware cabling.
Table 19. Cable Interconnect Events
Description Severity Cause
Cable sensor <Name/
Location>Configuration error
was asserted.
Critical This event is generated when the cable is
not connected or is incorrectly
connected.
Cable sensor <Name/
Location>Connection was
asserted.
Information This event is generated when the earlier
cable connection error was corrected.
The <name> cable or
interconnect is not connected
or is improperly connected.
Critical This event is generated when the named
cable or interconnect is not connected or
is incorrectly connected.
The <name> cable or
interconnect is connected.
Information This event is generated when named
cable or interconnect earlier cable or
interconnect connection error was
corrected.
Battery Events
Table 20. Battery Events
Description Severity Cause
<Battery sensor Name/
Location>Failed was asserted
Critical This event is generated when the sensor
detects a failed or missing battery.
<Battery sensor Name/
Location>Failed was
deasserted
Information This event is generated when the earlier
failed battery was corrected.
<Battery sensor Name/
Location>is low was asserted
Warning This event is generated when the sensor
detects a low battery condition.
<Battery sensor Name/
Location>is low was
deasserted
Information This event is generated when the earlier
low battery condition was corrected.
The <Battery sensor Name/
Location> battery is low.
Warning This event is generated when the sensor
detects a low battery condition.
213