Reference Guide

Table Of Contents
Event Message Severity Cause
Memory Mirrored redundancy
lost.
Critical This event is generated when redundancy
is lost in a mirrored memory configuration.
Memory Mirrored redundancy
regained.
Information This event is generated when the
redundancy lost or degraded earlier is
regained in a mirrored memory
configuration.
Memory Spared redundancy
degraded.
Warning This event is generated when there is a
memory failure in a spared memory
configuration.
Memory Spared redundancy
lost.
Critical This event is generated when redundancy
is lost in a spared memory configuration.
Memory Spared redundancy
regained.
Information This event is generated when the
redundancy lost or degraded earlier is
regained in a spared memory
configuration.
Memory RAID is redundant.
Information This event is generated when the memory
redundancy mode has change to RAID
redundant.
Memory RAID redundancy is
lost. Check memory device at
location(s) <DIMM number>.
Critical This event is generated when redundancy
is lost in a RAID-configured memory
configuration.
Memory RAID redundancy is
degraded. Check memory device
at location(s) <DIMM number
>.
Warning This event is generated when there is a
memory failure in a RAID-configured
memory configuration.
Memory is not redundant.
Information This event is generated when the memory
redundancy mode has change to
nonredundant.
Memory mirror is redundant.
Information This event is generated when the memory
redundancy mode has change to mirror
redundant.
Memory mirror redundancy is
lost. Check memory device at
location(s) <DIMM number>.
Critical This event is generated when redundancy
is lost in a mirror-configured memory
configuration.
Memory mirror redundancy is
degraded. Check memory device
at location <DIMM number >.
Warning This event is generated when there is a
memory failure in a mirror-configured
memory configuration.
Memory spare is redundant.
Information This event is generated when the memory
redundancy mode has change to spare
redundant.
Memory spare redundancy is
lost. Check memory device at
location <DIMM number>.
Critical This event is generated when redundancy
is lost in a sparer-configured memory
configuration.
203