Event Message Severity Cause
The <Sensor Name/ Location> temperature is outside
of range.
Critical Temperature of the backplane, system board, system
inlet, or the carrier in the specified system <Sensor
Name/Location> is outside of normal operating range.
The <Sensor Name/ Location> temperature is within
range.
Information Temperature of the backplane, system board, system
inlet, or the carrier in the specified system <Sensor
Name/Location> returned to a normal operating
range.
Voltage Sensor Events
The voltage sensor event messages monitor the number of volts across critical components. These messages provide status and
warning information for voltage sensors for a particular chassis.
Table 6. Voltage Sensor Events
Event Message Severity Cause
<Sensor Name/Location>
voltage sensor detected a
failure <Reading> where
<Sensor Name/Location> is the
entity that this sensor is
monitoring. Reading is
specified in volts. For
example, 3.860 V.
Critical The voltage of the monitored device has
exceeded the critical threshold.
<Sensor Name/Location>
voltage sensor state
asserted.
Critical The voltage specified by <Sensor Name/
Location> is in critical state.
<Sensor Name/Location>
voltage sensor state de-
asserted.
Information The voltage of a previously reported
<Sensor Name/Location> is returned to
normal state.
<Sensor Name/Location>
voltage sensor detected a
warning <Reading>.
Warning Voltage of the monitored entity <Sensor
Name/Location> exceeded the warning
threshold.
<Sensor Name/Location>
voltage sensor returned to
normal <Reading>.
Information The voltage of a previously reported
<Sensor Name/Location> is returned to
normal state.
The <Sensor Name/Location>
voltage is less than the
lower warning threshold.
Warning Voltage of the monitored Entity <Sensor
Name/ Location> exceeded the warning
threshold.
The <Sensor Name/Location>
voltage is less than the
lower critical threshold.
Critical Voltage of the monitored Entity <Sensor
Name/ Location> exceeded the critical
threshold.
The <Sensor Name/Location>
voltage is greater than the
upper warning threshold.
Warning Voltage of the monitored Entity <Sensor
Name/ Location> exceeded the warning
threshold.
The <Sensor Name/Location>
voltage is greater than the
upper critical threshold.
Critical Voltage of the monitored Entity <Sensor
Name/ Location> exceeded the critical
threshold.