Reference Guide

Table Of Contents
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2211
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751
Event ID — 2305
Description The physical disk is too small to be used for a rebuild.
Severity Warning / Non-critical
Cause and Action Cause: The physical disk is too small to rebuild the data.
Action: Remove the physical disk and insert a new physical disk that is the same size or larger than the disk
that is being rebuilt. The new physical disk must also use the same technology (for example, SAS or SATA)
as the disk being rebuilt. If the rebuild does not start automatically after you have inserted a suitable physical
disk, then run the Rebuild task. See the Server Administrator Storage Management User’s Guide for more
information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2326
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2306
Description
Bad block table is 80% full.
Severity Warning / Non-critical
Cause and Action Cause: The bad block table is used for remapping bad disk blocks. This table fills, as bad disk blocks are
remapped. When the table is full, bad disk blocks can no longer be remapped, and disk errors can no longer
be corrected. At this point, data loss can occur. The bad block table is now 80% full.
Action: Back up your data. Replace the disk generating this alert and restore from back up.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2307
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2307
Description
Bad block table is full. Unable to log block %1.