Reference Guide

Table Of Contents
Event ID — 2281
Description Virtual disk has inconsistent data.
Severity OK / Normal / Informational
Cause and Action Cause: The virtual disk has inconsistent data. This may be caused when a power loss or system shutdown
occurs while data is being written to the virtual disk. This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2127
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1201
Event ID — 2282
Description Hot spare SMART polling failed.
Severity Critical / Failure / Error
Cause and Action Cause: The controller firmware attempted a SMART polling on the hot spare but was unable to complete it.
The controller has lost communication with the hot spare.
Action: Check the health of the disk assigned as a hot spare. You may need to replace the disk and reassign
the hot spare. Make sure the cables are attached securely. See the Server Administrator Storage
Management User’s Guide, for more information on checking the cables.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2071
SNMP Trap
Numbers
904
Event ID — 2283
Description
A redundant path is broken.
Severity Warning / Non-critical
Cause and Action Cause: The controller has two connectors that are connected to the same enclosure. The communication
path on one connector has lost connection with the enclosure. The communication path on the other
connector is reporting this loss.
Action: Make sure the cables are attached securely and both enclosure management modules (EMMs) are
healthy. See the Cables Attached Correctly section for more information on checking the cables.
Related Alert
Information
Clear Alert Number: 2284
Related Alert Number: None
129