Reference Guide
Cause A voltage sensor in the specified system exceeded its failure threshold. The sensor
location, chassis location, previous state, and voltage sensor value information is
provided.
Event ID — 1155
Description
Voltage sensor detected a non-recoverable value Sensor
location: <Location in chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
If sensor type is not discrete:
Voltage sensor value (in Volts): <Reading>
If sensor type is discrete:
Discrete voltage state: <State>
Severity Error
Cause A voltage sensor in the specified system detected an error from which it cannot
recover. The sensor location, chassis location, previous state, and voltage sensor
value information is provided.
Current Sensor Messages
The current sensors listed measure the amount of current (in amperes) that is traversing critical
components. Current sensor messages provide status and warning information for current sensors in a
particular chassis.
Event ID – 1200
Description
Current sensor has failed Sensor location: <Location in
chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
If sensor type is not discrete:
Current sensor value (in Amps): <Reading> OR
Current sensor value (in Watts): <Reading>
If sensor type is discrete:
39