Reference Guide
Chassis location: <Name of chassis>
Previous state was: <State>
If sensor type is not discrete:
Temperature sensor value (in degrees Celsius): <Reading>
If sensor type is discrete:
Discrete temperature state: <State>
Severity Error
Cause A temperature sensor on the backplane board, system board, or drive carrier in the
specified system exceeded its failure threshold. The sensor location, chassis
location, previous state, and temperature sensor value are provided.
Event ID — 1055
Description
Temperature sensor detected a non-recoverable value Sensor
location: <Location in chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
If sensor type is not discrete:
Temperature sensor value (in degrees Celsius): <Reading>
If sensor type is discrete:
Discrete temperature state: <State>
Severity Error
Cause A temperature sensor on the backplane board, system board, or drive carrier in the
specified system detected an error from which it cannot recover. The sensor
location, chassis location, previous state, and temperature sensor value information
is provided.
Cooling Device Messages
The cooling device sensors listed monitor how well a fan is functioning. Cooling device messages
provide status and warning information for fans in a particular chassis.
Event ID — 1100
Description
Fan sensor has failed Sensor location: <Location in chassis>
Chassis location: <Name of chassis>
34