Reference Guide

Action: All physical disks in the virtual disk must use the same technology. You
cannot use both SAS and SATA physical disks in the same virtual disk. Remove the
physical disk and insert a new physical disk that uses the correct technology. If the
rebuild does not start automatically after you have inserted a suitable physical disk,
then run the Rebuild task.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2326
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2368
Description The SCSI Enclosure Processor (SEP) has been rebooted as part of the firmware
download operation and is unavailable until the operation completes.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2049, 2052, 2162, 2292
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
851
Event ID — 2369
Description Virtual Disk Redundancy has been degraded.
Severity OK / Normal / Informational
Cause and Action Cause: A physical disk in a RAID 6 virtual disk has either failed or been removed.
Action: Replace the missing or failed physical disk.
Related Alert
Information
Clear Alert Number: 2121
Related Alert Number: 2048, 2049, 2050, 2076, 2346
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1201
179