Reference Guide
Action: Replace the physical disk that contains the disk errors. Review other alert
messages to identify the physical disk that has errors. If the virtual disk is redundant,
you can replace the physical disk and continue using the virtual disk. If the virtual
disk is non-redundant, you may need to recreate the virtual disk after replacing the
physical disk. After replacing the physical disk, run Check Consistency to check the
data.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2081
SNMP Trap
Numbers
1204
Event ID — 2341
Description The Check Consistency made corrections and completed.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1201
Event ID — 2342
Description The Check Consistency found inconsistent parity data. Data redundancy may be
lost.
Severity Warning / Non-critical
Cause and Action Cause: The data on a source disk and the redundant data on a target disk is
inconsistent.
Action: Restart the Check Consistency task. If you receive this alert again, check
the health of the physical disks included in the virtual disk. Review the alert
messages for significant alerts related to the physical disks. If you suspect that a
physical disk has a problem, replace it and restore from backup.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2341, 2343
169