Reference Guide

Related Alert
Information
Clear Alert Number: 2325
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
1004
Event ID — 2325
Description The power supply cable has been inserted.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Status: Alert 2325 is a clear alert for alerts 2324 and 2312.
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1001
Event ID — 2326
Description A foreign configuration has been detected.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes. The controller has physical disks
that were moved from another controller. These physical disks contain virtual disks
that were created on the other controller. See the Import Foreign Configuration
and Clear Foreign Configuration section in the Server Administrator Storage
Management User’s Guide for more information.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751
Event ID — 2327
Description The NVRAM has corrupted data. The controller is reinitializing the NVRAM.
163