Reference Guide

Event ID — 2298
Description The enclosure has a bad sensor %1.
Severity Warning / Non-critical
Cause and Action Cause: The enclosure has a bad sensor. The enclosure sensors monitor the fan
speeds, temperature probes, and so on. The % indicates a substitution variable. The
text for this substitution variable is displayed with the alerts in the alert log and can
vary depending on the situation.
Action: See the hardware documentation for more information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2090
SNMP Trap
Numbers
853
Event ID — 2299
Description Bad PHY %1
Severity Critical / Failure / Error
Cause and Action Cause: There is a problem with a physical connection or PHY. The %1 indicates a
substitution variable. The text for this substitution variable is displayed with the alert
in the alert log and can vary depending on the situation.
Action: Contact your technical support.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
854
Event ID — 2300
Description The enclosure is unstable.
Severity Critical / Failure / Error
Cause and Action Cause: The controller is not receiving a consistent response from the enclosure.
There could be a firmware problem or an invalid cabling configuration. If the cables
are too long, they degrade the signal.
153