Reference Guide
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2098, 2161, 2196
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
901
Event ID — 2206
Description The only hot spare available is a SATA disk. SATA disks cannot replace SAS disks.
Severity Warning / Non-critical
Cause and Action Cause: The only physical disk available to be assigned as a hot spare is using SATA
technology. The physical disks in the virtual disk are using SAS technology. Because
of this difference in technology, the hot spare cannot rebuild data if one of the
physical disks in the virtual disk fails.
Action: Add a SAS disk that is large enough to be used as the hot spare and assign
it as a hot spare.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2207
Description The only hot spare available is a SAS disk. SAS disks cannot replace SATA disks.
Severity Warning / Non-critical
Cause and Action Cause: The only physical disk available to be assigned as a hot spare is using SAS
technology. The physical disks in the virtual disk are using SATA technology.
Because of this difference in technology, the hot spare cannot rebuild data if one
of the physical disks in the virtual disk fails.
Action: Add a SATA disk that is large enough to be used as the hot spare and assign
the new disk as a hot spare.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
120