Reference Guide
Local Response Agent (LRA) Number: 2050
SNMP Trap
Numbers
103
Event ID — 2169
Description The controller battery needs to be replaced.
Severity Critical / Failure / Error
Cause and Action Cause: The controller battery cannot be recharged. The battery may be old or it
may have been already recharged the maximum number of times. In addition, the
battery charger may not be working.
Action: Replace the battery pack.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2118
Local Response Agent (LRA) Number: 2101
SNMP Trap
Numbers
1154
Event ID — 2170
Description The controller battery charge level is normal.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1151
Event ID — 2171
Description The controller battery temperature is above normal.
Severity Warning / Non-critical
Cause and Action Cause: The battery may be recharging, the room temperature may be too hot, or
the fan in the system may be degraded or failed.
106