Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR61
Message The rebuild of arg1 failed due to errors on the source physical disk.
Arguments arg1 = physical disk
Detailed
Description
It is not possible to rebuild data that resides on a defective disk.
Recommended
Response Action
Replace the source disk and restore data from backup.
Category Storage (PDR = Physical Disk)
Severity Severity 1 (Critical)
Trap/EventID 4345
OMSA Event ID 2347
OMSA Trap ID 90400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR62
Message The rebuild failed due to errors on the target arg1 .
Arguments arg1 = physical disk
Detailed
Description
It is not possible to rebuild data that resides on a defective disk.
960