Reference Guide

Table Of Contents
PDR57
Message Bad block table on arg1 is full. Unable to log block arg2 .
Arguments arg1 = physical disk, arg2 = logical block address
Detailed
Description
The bad block table is the table used for remapping bad disk blocks. This table fills
as bad disk blocks are remapped. When the table is full, bad disk blocks are no
longer remapped, which means that disk errors are no longer corrected. At this
point, data loss can occur.
Recommended
Response Action
Replace the disk generating this message and restore from a backup copy. You
may have lost data.
Category Storage (PDR = Physical Disk)
Severity Severity 1 (Critical)
Trap/EventID 4345
OMSA Event ID 2307
OMSA Trap ID 90400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR58
Message arg1 is incompatible.
Arguments arg1 = PD Name
Detailed
Description
A user attempted to replace a disk with another disk that is using an incompatible
technology. For example, replaced one side of a mirror with a SAS disk when the
other side of the mirror is using SATA technology.
Recommended
Response Action
Refer to the hardware documentation for information on replacing disks.
Category Storage (PDR = Physical Disk)
Severity Severity 2 (Warning)
Trap/EventID 4346
957