Reference Guide

Table Of Contents
Trap/EventID 4346
OMSA Event ID 2305
OMSA Trap ID 90300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR56
Message Bad block table on arg1 is 80% full.
Arguments arg1 = physical disk
Detailed
Description
The bad block table is the table used for remapping bad disk blocks. This table fills
as bad disk blocks are remapped. When the table is full, bad disk blocks are no
longer remapped, which means that disk errors are no longer corrected. At this
point, data loss can occur. The bad block table is now 80 percent full.
Recommended
Response Action
Replace the disk generating this message.
Category Storage (PDR = Physical Disk)
Severity Severity 2 (Warning)
Trap/EventID 4346
OMSA Event ID 2306
OMSA Trap ID 90300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
956