Reference Guide

Table Of Contents
Detailed
Description
The controller has two connectors that are connected to the same enclosure. The
communication path on one connector has lost connection with the enclosure.
The communication path on the other connector is reporting this loss.
Recommended
Response Action
Make sure the cables are attached securely. See the Cables Attached Correctly
section for more information on checking the cables. Make sure both Enclosure
Management Modules (EMMs) are healthy.
Category Storage (PDR = Physical Disk)
Severity Severity 2 (Warning)
Trap/EventID 4346
OMSA Event ID 2283
OMSA Trap ID 90300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR53
Message A redundant path has been restored for arg1 .
Arguments arg1 = PD Name
Detailed
Description
This alert is provided for informational purposes.
Recommended
Response Action
No response action is required.
Category Storage (PDR = Physical Disk)
Severity Severity 3 (Informational)
Trap/EventID 4347
OMSA Event ID 2284
OMSA Trap ID 90100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
954