Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR51
Message Hot spare arg1 SMART polling has failed. arg2
Arguments arg1 = physical disk, arg2 = args
Detailed
Description
The controller firmware attempted to do SMART polling on the hot spare but could
not complete the SMART polling. The controller may have lost communication
with the hot spare.
Recommended
Response Action
Verify the health of the disk assigned as a hot spare. Replace the disk and reassign
the hot spare. Make sure the cables are attached securely. See the storage
hardware documentation for more information on checking the cables.
Category Storage (PDR = Physical Disk)
Severity Severity 1 (Critical)
Trap/EventID 4345
OMSA Event ID 2282
OMSA Trap ID 90400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR52
Message A redundant path is broken.
953