Reference Guide

Table Of Contents
Arguments arg1 = PD Name
Detailed
Description
A physical disk has been removed from the disk group. This alert can also be
caused by loose or defective cables or by problems with the enclosure.
Recommended
Response Action
Do one of the following: 1) If a physical disk was removed from the disk group,
either replace the disk or restore the original disk. Identify the disk that was
removed by locating the disk that has a red "X" for its status. 2) Perform a rescan
after replacing or restoring the disk. 3) If a disk was not removed from the disk
group, then check for cable problems. Refer to product documentation for more
information on checking the cables. 4) Make sure that the enclosure is powered
on. 5) If the problem persists, check the enclosure documentation for further
diagnostic information.
Category Storage (PDR = Physical Disk)
Severity Severity 2 (Warning)
Trap/EventID 4346
OMSA Event ID 2049
OMSA Trap ID 90300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR50
Message Insufficient space on the global hot spare arg1 .
Arguments arg1 = PD Name
Detailed
Description
The global hot spare is not large enough to protect all virtual disks that reside on
the controller.
Recommended
Response Action
Assign a larger disk as the global hot spare.
Category Storage (PDR = Physical Disk)
Severity Severity 2 (Warning)
Trap/EventID 4346
OMSA Event ID 2277
OMSA Trap ID 90300
952