Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR43
Message The clear operation on arg1 has completed.
Arguments arg1 = physical disk
Detailed
Description
This message is generated after a clear operation completes on a physical disk.
Recommended
Response Action
No response action is required.
Category Storage (PDR = Physical Disk)
Severity Severity 3 (Informational)
Trap/EventID 4347
OMSA Event ID 2269
OMSA Trap ID 90100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR44
Message The clear operation on arg1 failed.
Arguments arg1 = physical disk
Detailed
Description
A Clear task was being performed on a physical disk but the task was interrupted
and did not complete successfully. The controller may have lost communication
with the disk, the disk was removed, or the cables may be loose or defective.
Recommended
Response Action
Verify that the disk is present and not in a Failed state. Make sure the cables are
attached securely. See the storage hardware documentation for more information
on checking the cables. Restart the Clear task.
Category Storage (PDR = Physical Disk)
948