Reference Guide

Table Of Contents
Arguments arg1 = PD Name
Detailed
Description
The hot spare is no longer required because the virtual disk it was assigned to has
been deleted.
Recommended
Response Action
No response action is required.
Category Storage (PDR = Physical Disk)
Severity Severity 3 (Informational)
Trap/EventID 4347
OMSA Event ID 2205
OMSA Trap ID 90100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR35
Message The only hot spare available is a SATA disk arg1 .
Arguments arg1 = PD Name
Detailed
Description
The only physical disk available to be assigned as a hot spare is using SATA
technology. The physical disks in the virtual disk are using SAS technology. Because
of this difference in technology, the hot spare cannot rebuild data if one of the
physical disks in the virtual disk fails.
Recommended
Response Action
Add a SAS disk that is large enough to be used as the hot spare and assign the new
disk as a hot spare.
Category Storage (PDR = Physical Disk)
Severity Severity 2 (Warning)
Trap/EventID 4346
OMSA Event ID 2206
OMSA Trap ID 90300
942