Reference Guide

Table Of Contents
PDR29
Message Rebuild on arg1 completed with error(s).
Arguments arg1 = PD Name
Detailed
Description
See A Rebuild Completes with Errors for more information.
Recommended
Response Action
See A Rebuild Completes with Errors for more information.
Category Storage (PDR = Physical Disk)
Severity Severity 1 (Critical)
Trap/EventID 4345
OMSA Event ID 2163
OMSA Trap ID 90400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR3
Message arg1 is not functioning correctly.
Arguments arg1 = PD Name
Detailed
Description
The RAID Controller may not be able to read/write data to the physical disk drive
indicated in the message. This may be due to a failure with the physical disk drive
or because the physical disk drive was removed from the system.
Recommended
Response Action
Remove and re-insert the physical disk drive identified in the message and make
sure the physical disk drive is inserted properly. If the issue persists, replace the
physical disk drive.
Category Storage (PDR = Physical Disk)
Severity Severity 1 (Critical)
Trap/EventID 4345
938