Reference Guide

Table Of Contents
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR23
Message SMART warning degraded for arg1
Arguments arg1 = PD Name
Detailed
Description
A disk is degraded and has received a SMART alert (predictive failure). The disk is
likely to fail in the near future.
Recommended
Response Action
Replace the disk that has received the SMART alert. If the physical disk is a member
of a non-redundant virtual disk, then back up the data before replacing the disk.
Removing a physical disk that is included in a non-redundant virtual disk will cause
the virtual disk to fail and may cause data loss.
Category Storage (PDR = Physical Disk)
Severity Severity 2 (Warning)
Trap/EventID 4346
OMSA Event ID 2110
OMSA Trap ID 90300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR24
Message Failure prediction threshold exceeded on arg1 due to test. No action needed.
Arguments arg1 = PD Name
Detailed
Description
A disk has received a SMART alert (predictive failure) due to test conditions.
Recommended
Response Action
No response action is required.
Category Storage (PDR = Physical Disk)