Reference Guide

Table Of Contents
Severity Severity 1 (Critical)
OMSA Event ID 2183
OMSA Trap ID 90400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
PDR22
Message SMART warning temperature for arg1
Arguments arg1 = PD Name
Detailed
Description
A disk has reached an unacceptable temperature and received a SMART alert
(predictive failure). The disk is likely to fail in the near future.
Recommended
Response Action
Do the following: 1) Determine why the physical disk reached an unacceptable
temperature. For example, a fan failure, incorrect thermostat settings, or the room
temperature may be too hot or cold. 2) Verify that the fans in the server or
enclosure are working. 3) If the physical disk is in an enclosure, check the
thermostat settings and examine whether the enclosure is located near a heat
source. Verify the enclosure has enough ventilation and that the room temperature
is not too hot. Refer to the enclosure documentation for more diagnostic
information. 4) If you cannot identify why the disk has reached an unacceptable
temperature, then replace the disk. If the physical disk is a member of a non-
redundant virtual disk, then back up the data before replacing the disk. Removing a
physical disk that is included in a non-redundant virtual disk causes the virtual disk
to fail and may cause data loss.
Category Storage (PDR = Physical Disk)
Severity Severity 2 (Warning)
Trap/EventID 4346
OMSA Event ID 2109
OMSA Trap ID 90300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *