Reference Guide

Table Of Contents
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
PDR207
Message Unable to assign arg1 as a dedicated hot spare.
Arguments arg1 = physical disk name
Detailed
Description
Unable to assign the physical disk as a dedicated hot spare because the selected
disk size does not meet the size requirements of the target Virtual Disk.
Recommended
Response Action
Select a physical disk that matches the size required for the disks used in the target
Virtual Disk, and retry the operation.
Category Storage (PDR = Physical Disk)
Severity Severity 3 (Informational)
OMSA Event ID 2386
OMSA Trap ID 90100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
PDR208
Message Instant Secure Erase operation successfully completed on arg1 .
Arguments arg1 = physical disk name
Detailed
Description
The secure erase operation successfully completed on the Self-Encrypting Drive
(SED) identified in the message.
927