Reference Guide

Table Of Contents
PDR20
Message SMART configuration change for arg1 .
Arguments arg1 = PD Name
Detailed
Description
A disk has received a SMART alert (predictive failure) after a configuration change.
The disk is likely to fail in the near future.
Recommended
Response Action
Replace the disk that has received the SMART alert. If the physical disk is a member
of a non-redundant virtual disk, then back up the data before replacing the disk.
Removing a physical disk that is included in a non-redundant virtual disk will cause
the virtual disk to fail and may cause data loss.
Category Storage (PDR = Physical Disk)
Severity Severity 1 (Critical)
Trap/EventID 4345
OMSA Event ID 2107
OMSA Trap ID 90400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR206
Message arg1 is a solid state drive (SSD) that is not supported by the controller.
Arguments arg1 = physical disk name
Detailed
Description
The storage controller does not support the attached SSD devices.
Recommended
Response Action
Remove SSD devices not supported by the controller, and retry the operation.
Category Storage (PDR = Physical Disk)
Severity Severity 2 (Warning)
OMSA Event ID 2382
OMSA Trap ID 90300
926