Reference Guide

Table Of Contents
PDR18
Message Global hot spare unassigned from arg1 .
Arguments arg1 = PD Name
Detailed
Description
A physical disk assigned as a hot spare was unassigned and is no longer functioning
as a hot spare. The physical disk was unassigned by a user or automatically
unassigned by Storage Management. Storage Management unassigns hot spares
were used to rebuild data. Once the data is rebuilt onto the hot spare, the hot spare
becomes a member of the virtual disk and is no longer assigned as a hot spare.
Assign a new hot spare to maintain data protection in this situation.
Recommended
Response Action
Although this alert is provided for informational purposes, you may need to assign
a new hot spare to the virtual disk. See Protecting Your Virtual Disk with a Hot
Spare for more information.
Category Storage (PDR = Physical Disk)
Severity Severity 3 (Informational)
Trap/EventID 4347
OMSA Event ID 2099
OMSA Trap ID 90100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
PDR19
Message SMART FPT exceeded for arg1 .
Arguments arg1 = PD Name
Detailed
Description
A disk on the specified controller has received a SMART alert (predictive failure)
indicating that the disk is likely to fail in the near future.
Recommended
Response Action
Replace the disk that has received the SMART alert. If the physical disk is a member
of a non-redundant virtual disk, then back up the data before replacing the disk.
Removing a physical disk that is included in a non-redundant virtual disk causes the
virtual disk to fail and may cause data loss.
Category Storage (PDR = Physical Disk)
924